• banner_01

Fish Collagen Filtration Experiment Report

Product Information

Product Name: Fish Collagen Solution

Sample Type: Fish Collagen Powder

Test Date: January 2026

Tested By: Technical Service Department

 

Objective

To evaluate the filtration performance of different depth filter sheets and determine the most suitable filtration solution for removing insoluble particles and contaminants from fish collagen solution while maintaining product quality and filtration efficiency.

Materials and Equipment

Equipment

Equipment Specification Quantity
Filter Holder Φ47 mm 1
Beaker 1000 mL 4
Turbidity Meter 0–1000 NTU 1
Particle Size Analyzer Laser Diffraction Type 1
Magnetic Stirrer Temperature Controlled 1

Filter Media

SCP-335 Depth Filter Sheet
SCP-336 Depth Filter Sheet
SCH-660 Depth Filter Sheet

Test Material

Fish collagen powder supplied for filtration evaluation.

Experimental Procedure

Preparation

Clean all equipment using alkaline and acidic cleaning solutions.

Rinse thoroughly with purified water until pH reaches 7.0–7.5.

Install filter sheets in the filtration holder.

Flush filter sheets with purified water at approximately 50 L/m² before use.

Prepare fish collagen solution using a 1:1 ratio of collagen powder to purified water.

Filtration Process

Dissolve fish collagen powder in purified water at approximately 70°C.

Maintain the solution at 60–70°C with continuous stirring.

Measure initial turbidity and particle size distribution.

Filter the solution separately through SCP-335, SCP-336, and SCH-660 filter sheets.

Collect filtrate samples for analysis.

Perform an additional recirculation filtration test using SCP-335 filtrate.

Record filtration throughput, turbidity reduction, and particle size distribution before and after filtration.

Results

Filtration Performance Summary

Filter Sheet Filtration Rate Clarity Improvement Particle Removal Efficiency
SCP-336 Good Moderate Good
SCH-660 Moderate Good Very Good
SCP-335 Excellent Excellent Excellent
SCP-335 Recirculation Excellent Outstanding Outstanding

Particle Size Analysis

Particle analysis indicated that the majority of insoluble contaminants were distributed between 1 μm and 1000 μm, with a significant concentration in the 50–300 μm range.

After filtration, all tested filter sheets reduced the concentration of large particles, while SCP-335 demonstrated the highest overall removal efficiency.

Turbidity Reduction

Filtration significantly improved solution clarity and reduced turbidity. The best results were obtained using SCP-335 with recirculation filtration.

Conclusion

  1. All tested filter sheets effectively reduced insoluble particles and improved the appearance of the fish collagen solution.
  2. SCP-335 provided the best balance of filtration efficiency, throughput, and particle removal performance.
  3. For enhanced removal of particles larger than 50 μm, a second filtration pass using SCP-335 or a two-stage SCP-335 filtration configuration is recommended.
  4. Particle size analysis confirmed that larger visible contaminants can be effectively removed through depth filtration, resulting in improved product clarity and quality.

Post time: Jun-01-2026

WeChat

whatsapp